Commit 95fdb533
95fdb5334a7fMerged
Yukihiro "Matz" Matsumoto <[email protected]> · 6 months ago · 1 file · ~1 modified
Description
fix(codegen): infer_type CallNode cache-miss falls back to obj-recv method return
infer_type's CallNode fallback returned "int" when:
- the call wasn't a lambda call
- the recv wasn't sub-arith
- walk_and_cache hadn't annotated it (or annotated to stale int)
For a d.call where d is a user-class instance with a bigint-
returning call method, the static type defaulted to "int" and
the outer return wrapped the already-bigint emit with sp_bigint
_new_int — double wrap.
Add a generic obj-recv fallback: when recv resolves to obj_
and the class defines <mname>, return @cls_meth_returns's slot.
Promote-mode test count: 547 pass / 47 fail / 24 error -> 548 pass / 47 fail / 23 error. Default raise mode 618 / 0 / 0; optcarrot checksum 59662.
Co-Authored-By: Claude Opus 4.7 [email protected]
Details
- Commit
- 95fdb5334a7f
- Parent
- edd1240fa8f2
spinel_codegen.rbmodifiedView file
@@ -2755,6 +2755,35 @@
27552755
end27562756
end27572757
end2758+
# Generic `obj.method(...)` cache-miss path: when the recv is2759+
# statically a user-class instance and the class defines a method2760+
# of that name, route through cls_method_return so the now-2761+
# promoted return type flows up. Without this, promote-mode CallNodes2762+
# that walk_and_cache skipped (or that annotated as stale "int"2763+
# before the promote sweep) silently default to "int" and the2764+
# outer return / arith arms double-wrap with sp_bigint_new_int.2765+
cmp_recv_obj = @nd_receiver[nid]2766+
if cmp_recv_obj >= 02767+
cmp_recv_t_obj = base_type(infer_type(cmp_recv_obj))2768+
if is_obj_type(cmp_recv_t_obj) == 12769+
cmp_cn_obj = cmp_recv_t_obj[4, cmp_recv_t_obj.length - 4]2770+
cmp_ci_obj = find_class_idx(cmp_cn_obj)2771+
if cmp_ci_obj >= 02772+
cmp_names_obj = @cls_meth_names[cmp_ci_obj].split(";")2773+
cmp_returns_obj = @cls_meth_returns[cmp_ci_obj].split(";")2774+
cmp_jj_obj = 02775+
while cmp_jj_obj < cmp_names_obj.length2776+
if cmp_names_obj[cmp_jj_obj] == cmp_mname && cmp_jj_obj < cmp_returns_obj.length2777+
cmp_ret_obj = cmp_returns_obj[cmp_jj_obj]2778+
if cmp_ret_obj != ""2779+
return cmp_ret_obj2780+
end2781+
end2782+
cmp_jj_obj = cmp_jj_obj + 12783+
end2784+
end2785+
end2786+
end27582787
return "int"27592788
end27602789
if t == "IfNode"